‧AC‧
MEA938
Sinwan AC Motor, Dia.59 x L.36
Max. Loading 17W, IP55
  Rated
Voltage
Freq Rated
Loading
Input
Ref.
Loading
Speed
No Loading Free Running Locked Rotor
Seized Motor
No Loading
Staring
UL
Input Current Speed Input Current Voltage  
Model No VAC Hz Watt RPM

Watt

Amp RPM Watt Amp VAC  
MEA938AN11-1B** 115 50/60 17/15 2700/3150 12/11 0.16/0.14 2800/3480 22/20 0.21/0.18 37/44 £
MEA938AN11-2B** 115 50/60 13/11 2350/2600 10/8 0.12/0.10 2800/3590 17/15 0.16/0.15 39/47 £
MEA938AN11-3B** 115 50/60 9/7 1950/1850 6/5 0.09/0.06 2800/3495 12/10 0.12/0.09 42/50 £
MEA938AN22-1B** 230 50/60 17/15 2700/3150 12/11 0.11/0.09 2800/3480 22/20 0.12/0.10 37/44 £
MEA938AN22-2B** 230 50/60 13/11 3250/2600 10/8 0.07/0.06 28003590 17/15 0.11/0.09 39/47 £
MEA938AN22-3B** 230 50/60 9/7 1950/1850 6/5 0.05/0.04 2800/3495 12/10 0.07/0.05 42/50 £
  • **= DC / DR / UC / UR / DUC / DUR / NC / NR, for full model No. click “Nomenclature”.
    First *=D, U, DU, N description of shaft outlet position, second *=C, R description of motor rotating direction C-CW , R-CCW.
    Example: MEA938AN11-1BDR, **/DR= Shaft outlet- D type, motor rotating direction viewed from rotor CCW-R type
  • 100, 200, 240V or special voltages 12, 24, 28, 38, 42, 48, 380, 440, 480V... 50/60Hz, & any voltages available.
  • Dual speed High/Medium 1/2, Medium/Low 2/3 available on request.
  • Sinwan reserves the right to change data and improve electrical & mechanical design without notice, data tolerance +-10%
  •  
      Motor Type: External rotor, shaded pole, single phase, 2 pole, impedance protected
      IP Protection:
      Frame: Aluminum diecasting bracket & frame, 7 mounting holes dia.2.3mm or tapped M3
      Bearing: Two high precision permanently lubricated ball bearings
      Shaft: Stainless steel SUS420J2,dia.5, L. 30mm, optional configurations, CW or CCW on request
      Weight: 225 Gm (0.5Lb)
      Dielectric Strength: Over 1 min. At 1,5000VAC, 0.5mA, 50/60 Hz
      Insulation Resistance: Over 100 Mega Ohm at DC500V, between leads and frame
      Signal Output:
      Operating Temp: Acceptable -20°C~+65°C. Storage -30°C~+105°C (65%RH)
      Life Expectancy: Rated loading continuous duty 65K hours at 45°C, 40K at 60°C. MTBF 90K hrs at 35°C